10-chaw nres nkoj 10/100/1000M Media Converter (Ib hom Dual-fiber SC)
10-chaw nres nkoj 10/100/1000M Media Converter (Ib hom Dual-fiber SC)
Khoom nta:
Huizhou Changfei Optoelectronics Technology Co., Ltd. launched ib gigabit 8 optical 2 hluav taws xob ib hom dual-fiber optical transceiver hloov.Cov khoom lag luam tshiab no coj los ua ke qhov kev nce qib tshiab hauv 5G cov cuab yeej sib txuas lus thiab fiber ntau optic transceivers los muab cov kev daws teeb meem zoo tsim nyog rau cov ntaub ntawv sab nraum zoov.
Nrog rau qhov kev xav tau loj hlob ntawm kev kub ceev, txhim khu kev qha network kev sib txuas, cov lag luam niaj hnub nrhiav txoj hauv kev los txhim kho cov ntaub ntawv hloov pauv.Nrog Gigabit 8 Optical 2 Hluav Taws Xob Ib Hom Dual Fiber Media Converter Hloov, koj tuaj yeem ua tiav kev sib txuas lus sib txuas ntawm cov khoom siv sib txawv hauv koj lub network nrog kev siv hluav taws xob tsawg.
Ib qho tshwj xeeb ntawm cov khoom no yog nws 4 tus lej hu rau kev teeb tsa yooj yim thiab teeb tsa.Tsis muaj teeb meem ntxiv ntawm kev teeb tsa nyuaj - tsuas yog hu rau hauv qhov chaw koj xav tau thiab txaus siab rau qhov kev sib txuas zoo thiab muaj txiaj ntsig zoo.Tsis tas li ntawd, SC interface ua kom muaj kev ruaj ntseg thiab ruaj khov, txo qhov kev pheej hmoo ntawm cov ntaub ntawv poob lossis cuam tshuam.
Txhawm rau kom ntseeg tau lub network pom thiab saib xyuas, Gigabit 8 Optical 2 Hluav Taws Xob Ib Leeg Hom Dual Fiber Media Converter Hloov yog nruab nrog dynamic LED ntsuas.Cov teeb no muab cov lus teb rau lub sijhawm tiag tiag ntawm cov xwm txheej kev sib txuas, ua kom muaj kev daws teeb meem sai thiab daws teeb meem.
Ntawm Huizhou Changfei Optoelectronics Technology Co., Ltd., peb nkag siab txog qhov tseem ceeb ntawm kev txhim khu kev lag luam hauv lub network niaj hnub no.Tias yog vim li cas peb tsim cov khoom no nrog kev saib xyuas zoo tshaj plaws thiab kev ua haujlwm zoo.Peb cov kws tshaj lij hauv 5G cov cuab yeej sib txuas lus thiab fiber ntau optic transceivers ua rau peb tsim cov khoom lag luam tshaj li cov qauv kev lag luam thiab ua tau raws li cov kev hloov pauv ntawm cov ntaub ntawv chaw.
Cov khoom no tsis yog tsuas yog muaj zog, tab sis kuj muaj ntau yam.Txawm hais tias koj tab tom nrhiav los tsim cov ntaub ntawv tshiab sab nraum zoov lossis txhim kho kev ua tau zoo ntawm koj cov kev tsim kho uas twb muaj lawm, Gigabit 8 Optical 2 Hluav Taws Xob Ib Hom Dual Fiber Media Converter Hloov yog qhov kev daws teeb meem zoo tshaj.
Huizhou Changfei Optoelectronic Technology Co., Ltd.Peb tau cog lus los muab peb cov neeg siv khoom nrog cov khoom lag luam saum toj kawg nkaus uas ua tau raws li lawv cov kev xav tau tshwj xeeb.Nrog rau peb cov khoom siv dav, suav nrog 10G core keyboards, industrial-qib huab network tswj cov keyboards, optical modules, thiab lwm yam, peb tau cog lus los tsav kev nce qib ntawm kev siv tshuab network.
Hauv kev xaus, Gigabit 8-optical 2-hluav taws xob ib leeg-hom dual-fiber media converter hloov yog qhov hloov pauv kev ua si hauv thaj chaw ntawm cov ntaub ntawv sab nraum zoov.Nrog nws cov kev siv hluav taws xob tsawg, 4-tus lej hu, SC interface thiab cov cim taw qhia dynamic LED, nws muaj kev sib xyaw ua ke zoo tshaj plaws ntawm kev yooj yim, kev ntseeg siab thiab kev ua haujlwm.Thov tso siab rau Huizhou Changfei Optoelectronics Technology Co., Ltd. los muab cov kev daws teeb meem hauv kev lag luam uas koj xav tau kom vam meej hauv lub hnub nyoog digital.
Technical Parameter:
Qauv | CF-8022 GSW-20 | |
Interface yam ntxwv | ||
Tsau Chaw nres nkoj | 2 * 10/100/1000Base-T RJ45 chaw nres nkoj 8 * 1000Base-X uplink SC fiber ntau chaw nres nkoj | |
Ethernet Chaw nres nkoj | 10/100/1000Base-T auto-sensing, puv / ib nrab duplex MDI / MDI-X tus kheej hloov | |
Twisted Pair Kev sib kis | 10BASE-T: Cat3,4,5 UTP(≤100 meter) 100BASE-T: Cat5e lossis tom qab UTP (≤100 meter) 1000BASE-T : Cat5e lossis tom qab UTP (≤100 meter) | |
Optical Chaw nres nkoj | Default optical module yog ib hom dual-fiber 20km, SC chaw nres nkoj | |
Wavelength / nrug | Ib hom: 1310nm 0 ~ 40KM, 1550nm 0 ~ 120KM | |
Chip Parameter | ||
Network raws tu qauv | IEEE 802.3 10BASE-T, IEEE 802.3i 10Base-T,IEEE 802.3u 100Base-TX, IEEE 802.3u 100Base-FX, IEEE 802.3x IEEE 802.3ab 1000Base-T; IEEE 802.3z 1000Base-X; | |
Kev xa tawm hom | Khw muag khoom thiab xa mus (Tag Nrho Hlau Ceev) | |
Hloov Peev Xwm | 20 Gbps | |
Buffer Nco | 14.88 Nws | |
MAC | 2 K | |
Qhov taw qhia LED | Fiber ntau | F1-F8 |
Ntawm lub rooj zaum RJ45 | 1-2 Yellow: Qhia PoE | |
1-2 Ntsuab: Qhia txog kev ua haujlwm hauv network | ||
Hwj chim | PWR (ntsuab) | |
Hwj chim | ||
Ua haujlwm Voltage | AC: 100-240V | |
Kev siv fais fab | Standby <3W, Full load <10W | |
Fais fab mov | DC: 5V / 2A industrial fais fab mov | |
Kev tiv thaiv xob laim & Daim ntawv pov thawj | ||
xob tiv thaiv | Kev tiv thaiv xob laim: 4KV 8/20us, Kev tiv thaiv qib: IP30 | |
Daim ntawv pov thawj | CCC; CE cim, lag luam;CE/LVD EN60950; FCC Tshooj 15 Chav B;RoHS | |
Lub cev Parameter | ||
Kev ua haujlwm TEMP | -20 ~ + 55 ° C; 5% ~ 90% RH Tsis condensing | |
Cia TEMP | -40 ~ + 85 ° C; 5% ~ 95% RH Tsis condensing | |
Qhov Loj (L * W * H) | 220mm * 101mm * 28mm | |
Kev teeb tsa | Desktop |
Khoom Loj:
Product Application Diagra:
Yuav ua li cas xaiv lub fiber optic transceiver?
Optical fiber transceivers rhuav tshem 100-meter txwv ntawm Ethernet cables hauv cov ntaub ntawv xa mus.Kev cia siab rau kev ua haujlwm siab hloov cov chips thiab lub peev xwm loj, thaum ua tiav qhov tsis thaiv kev sib kis thiab kev hloov pauv kev ua tau zoo, lawv kuj muab cov tsheb sib npaug, kev sib cais thiab kev tsis sib haum xeeb.Kev tshawb nrhiav yuam kev thiab lwm yam haujlwm ua kom muaj kev ruaj ntseg thiab ruaj khov thaum lub sijhawm xa cov ntaub ntawv.Yog li ntawd, cov khoom siv fiber ntau optic transceiver tseem yuav yog ib feem tseem ceeb ntawm kev tsim network tiag tiag rau lub sijhawm ntev.Yog li, peb yuav tsum xaiv fiber ntau optic transceivers li cas?
1. Chaw nres nkoj ua haujlwm kuaj
Feem ntau sim seb txhua qhov chaw nres nkoj tuaj yeem ua haujlwm li cas hauv lub xeev duplex ntawm 10Mbps, 100Mbps thiab ib nrab-duplex xeev.Nyob rau tib lub sijhawm, nws yuav tsum tau sim seb txhua qhov chaw nres nkoj tuaj yeem xaiv qhov kev sib kis ceev tshaj plaws thiab txiav txim siab qhov sib kis ntawm lwm cov khoom siv.Qhov kev xeem no tuaj yeem suav nrog hauv lwm qhov kev xeem.
2. Kev ntsuas kev sib haum xeeb
Nws tsuas yog ntsuas qhov kev sib txuas muaj peev xwm ntawm optical fiber transceiver thiab lwm yam khoom siv sib xws nrog Ethernet thiab Fast Ethernet (xws li daim npav network, HUB, Hloov, daim npav kho qhov muag, thiab hloov kho qhov muag).Qhov yuav tsum tau muaj peev xwm txhawb nqa kev sib txuas ntawm cov khoom sib xws.
3. Cable kev twb kev txuas yam ntxwv
Kuaj cov fiber ntau optic transceiver lub peev xwm los pab txhawb cov cables.Ua ntej, sim qhov kev sib txuas muaj peev xwm ntawm Qeb 5 network cables nrog qhov ntev ntawm 100m thiab 10m, thiab kuaj qhov muaj peev xwm sib txuas ntawm Qeb 5 network cables ntev (120m) ntawm ntau hom.Thaum lub sij hawm xeem, qhov chaw nres nkoj kho qhov muag ntawm lub transceiver yuav tsum muaj kev sib txuas muaj peev xwm ntawm 10Mbps thiab tus nqi ntawm 100Mbps, thiab qhov siab tshaj plaws yuav tsum muaj peev xwm txuas mus rau tag nrho-duplex 100Mbps yam tsis muaj qhov yuam kev.Qeb 3 twisted khub cables yuav tsis raug kuaj.Subtests tuaj yeem suav nrog hauv lwm qhov kev xeem.
4. Cov yam ntxwv kis tau tus mob (kev kis tus nqi poob ntawm cov ntaub ntawv pob ntawm qhov ntev sib txawv, kev sib kis ceev)
Nws tsuas yog kuaj cov pob ntawv poob tus nqi thaum lub optical fiber transceiver optical chaw nres nkoj xa cov ntaub ntawv sib txawv, thiab kev sib txuas ceev raws li qhov sib txawv ntawm kev sib txuas.Rau cov pob ntawv poob tus nqi, koj tuaj yeem siv cov ntawv xeem software muab los ntawm daim npav network los kuaj cov pob ntawv poob thaum lub pob ntawv loj yog 64, 512, 1518, 128 (yeem) thiab 1000 (yeem) bytes nyob rau hauv cov nqi sib txawv., tus naj npawb ntawm pob ntawv yuam kev, tus naj npawb ntawm cov pob ntawv xa thiab tau txais yuav tsum yog ntau tshaj 2,000,000.Kev ntsuas kev sib kis ceev tuaj yeem siv ua 3, ping thiab lwm yam software.
5. Lub compatibility ntawm tag nrho lub tshuab mus rau kis tau tus mob network raws tu qauv
Nws tsuas yog ntsuas qhov sib xws ntawm fiber ntau optic transceivers rau network raws tu qauv, uas tuaj yeem sim hauv Novell, Windows thiab lwm qhov chaw.Cov txheej txheem qis hauv qab no xws li TCP/IP, IPX, NETBIOS, DHCP, thiab lwm yam yuav tsum tau sim, thiab cov txheej txheem uas yuav tsum tau tshaj tawm yuav tsum tau sim.Optical transceivers yuav tsum tau los txhawb cov kev cai no (VLAN, QOS, COS, thiab lwm yam).
6. Qhov ntsuas qhov ntsuas qhov ntsuas
Kuaj seb qhov xwm txheej ntawm qhov taw qhia lub teeb puas zoo ib yam nrog cov lus piav qhia ntawm lub vaj huam sib luag thiab cov neeg siv phau ntawv, thiab seb nws puas zoo ib yam nrog cov xwm txheej tam sim no ntawm fiber ntau optic transceiver.