10-chaw nres nkoj 10/100/1000M WDM Media Converter (ib leeg-hom Ib-fiber SC)
10-chaw nres nkoj 10/100/1000M WDM Media Converter (ib leeg-hom Ib-fiber SC)
Khoom nta:
Tshaj tawm Gigabit 8 optical 2 hluav taws xob ib hom ib leeg-fiber 3km B kawg: qhov kawg daws rau cov ntaub ntawv sib txuas
Txais tos rau Huizhou Changfei Optoelectronics Technology Co., Ltd., ib lub chaw tsim khoom siv kev sib txuas lus nyob hauv Huizhou, Suav.Txij li thaum peb tsim nyob rau hauv 2009, peb muaj cov ntaub ntawv pov thawj ntawm kev ua tau zoo thiab peb txaus siab rau peb tus kheej uas muaj peev xwm muab cov khoom tshiab thiab cov khoom zoo kom tau raws li cov kev xav tau ntawm lub khw.Raws li lub tuam txhab kev lag luam high-tech, peb tsom mus rau 5G cov cuab yeej sib txuas lus, 10G core keyboards, fiber ntau optic transceivers thiab lwm yam khoom siv sib txuas lus.
Nyob rau niaj hnub no lub hnub nyoog ceev-paced digital, cov chaw zov me nyuam cov ntaub ntawv ua lub luag haujlwm tseem ceeb hauv kev ua kom muaj kev sib txuas tsis zoo thiab kev xa cov ntaub ntawv txhim khu kev qha.Raws li qhov xav tau kom siab dua bandwidth thiab kev sib txuas ceev nrawm txuas ntxiv mus ntxiv, nws yog qhov tseem ceeb rau kev nqis peev hauv kev siv thev naus laus zis uas tuaj yeem ua tau raws li cov kev xav tau no.Qhia tawm cov tswv cuab tshiab tshaj plaws ntawm peb cov khoom lag luam: Gigabit 8 Optical 2 Hluav Taws Xob Ib Hom Ib Leeg Fiber 3km B-kawg.
Peb Gigabit 8 optical 2 hluav taws xob ib hom ib leeg-fiber 3km B-kawg yog tshwj xeeb tsim los rau cov ntaub ntawv chaw kho qhov muag fiber ntau network thiab yog qhov kawg daws rau kev sib txuas zoo thiab txhim khu kev qha.Lub xeev-ntawm-lub-kos duab transceiver integrates seamlessly nrog fiber optic media converters thiab keyboards, ua rau cov ntaub ntawv chaw muab kev pab zoo tshaj thiab unmatched kev ntseeg.
Nrog nws cov yam ntxwv zoo kawg nkaus, peb cov khoom ua kom muaj kev sib txuam thiab txhim khu kev qha cov ntaub ntawv hloov chaw.Nws boasts gigabit cov ntaub ntawv hloov pauv tus nqi rau xob laim-ceev kev sib txuas lus thiab ua tau zoo ntawm cov ntaub ntawv loj heev.Txawm hais tias nws yog cov ntaub ntawv siv ntau heev, video streaming, lossis cov kev pabcuam huab cua, peb cov transceivers ua kom muaj kev ua haujlwm zoo, tsis muaj kev cuam tshuam thiab tshem tawm cov fwj hauv cov ntaub ntawv hauv lub network.
Tsis tas li ntawd, peb Gigabit 8 Optical 2 Hluav Taws Xob Ib Hom Ib Leeg Fiber 3km B-kawg muaj kev ruaj ntseg zoo heev los tiv thaiv koj cov ntaub ntawv chaw tsim kho.Nrog rau qhov ntsuas IP30, nws yog ruggedized tiv thaiv plua plav thiab khib nyiab, ua kom ntseeg tau, tsis muaj kev cuam tshuam kev ua tau zoo txawm tias nyob rau hauv ib puag ncig hnyav.Tsis tas li ntawd, nws qhov chaw nres nkoj hluav taws xob sab nraud txhawb nqa 4KV kev tiv thaiv xob laim, tiv thaiv koj cov cuab yeej muaj txiaj ntsig los ntawm lub zog hluav taws xob thiab hluav taws xob tsis ruaj khov.
Ntawm Huizhou Changfei Optoelectronics Technology Co., Ltd., peb tau cog lus los muab cov khoom siv sib txuas lus tshiab, zoo tshaj plaws kom tau raws li cov kev xav tau ntawm cov neeg siv khoom thoob ntiaj teb.Nrog lub hauv paus tsim khoom ntawm ntau tshaj 20,000 square meters thiab ib pab neeg mob siab rau ntau tshaj 30 tus kws tshaj lij, peb siv zog los muab kev ua tau zoo hauv txhua yam khoom.
Txhawm rau ua kom tiav, Gigabit 8 optical 2 hluav taws xob ib hom ib leeg-fiber 3km B kawg yog qhov kev daws teeb meem zoo tshaj plaws rau cov ntaub ntawv chaw kho qhov muag fiber ntau txuas.Peb cov transceivers sib txuas cov ntaub ntawv xa mus ceev ceev gigabit, cov yam ntxwv muaj kev nyab xeeb zoo xws li IP30 kev tiv thaiv, thiab cov chaw nres nkoj fais fab sab nraud nrog 4KV xob tiv thaiv kom tsis txhob muaj seamless, txhim khu kev qha thiab ruaj ntseg cov ntaub ntawv xa mus.Thov ntseeg tias Huizhou Changfei Photoelectric Technology Co., Ltd. tuaj yeem ua tau raws li tag nrho koj cov khoom siv sib txuas lus xav tau.
Technical Parameter:
Qauv | CF-8012 GSW-3B | |
Interface yam ntxwv | ||
Tsau Chaw nres nkoj | 2 * 10/100/1000Base-T RJ45 chaw nres nkoj 8 * 1000Base-X uplink SC fiber ntau chaw nres nkoj | |
Ethernet Chaw nres nkoj | 10/100/1000Base-T auto-sensing, puv / ib nrab duplex MDI / MDI-X tus kheej hloov | |
Twisted Pair Kev sib kis | 10BASE-T: Cat3,4,5 UTP(≤100 meter) 100BASE-T: Cat5e lossis tom qab UTP (≤100 meter) 1000BASE-T : Cat5e lossis tom qab UTP (≤100 meter) | |
Optical Chaw nres nkoj | Default optical module yog ib hom ib leeg-fiber 3km, SC chaw nres nkoj | |
Wavelength / nrug | A-kawg: RX1310nm / RX1550nm 0 ~ 40KM B-kawg: RX1550nm / RX1310nm 0 ~ 40KM | |
A-kawg: RX1490nm / RX1550nm 0 ~ 120KM B-kawg: RX1550nm / RX1490nm 0 ~ 120KM | ||
Chip Parameter | ||
Network raws tu qauv | IEEE 802.3 10BASE-T, IEEE 802.3i 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3u 100Base-FX, IEEE 802.3x IEEE 802.3ab 1000Base-T; IEEE 802.3z 1000Base-X; | |
Kev xa tawm hom | Khw muag khoom thiab xa mus (Tag Nrho Hlau Ceev) | |
Hloov Peev Xwm | 20 Gbps | |
Buffer Nco | 14.88 Nws | |
MAC | 2 K | |
Qhov taw qhia LED | Fiber ntau | FX1-FX8 |
Ntawm lub rooj zaum RJ45 | 1X-2X Yellow: Qhia PoE | |
1X-2X Ntsuab: Qhia txog kev ua haujlwm hauv network | ||
Hwj chim | PWR (ntsuab) | |
Hwj chim | ||
Ua haujlwm Voltage | AC: 100-240V | |
Kev siv fais fab | Standby <3W, Full load <10W | |
Fais fab mov | DC: 5V / 2A industrial fais fab mov | |
Kev tiv thaiv xob laim & Daim ntawv pov thawj | ||
xob tiv thaiv | Kev tiv thaiv xob laim: 4KV 8/20us, Kev tiv thaiv qib: IP30 | |
Daim ntawv pov thawj | CCC; CE cim, lag luam;CE/LVD EN60950; FCC Tshooj 15 Chav B;RoHS | |
Lub cev Parameter | ||
Kev ua haujlwm TEMP | -20 ~ + 55 ° C; 5% ~ 90% RH Tsis condensing | |
Cia TEMP | -40 ~ + 85 ° C; 5% ~ 95% RH Tsis condensing | |
Qhov Loj (L * W * H) | 220mm * 101mm * 28mm | |
Kev teeb tsa | Desktop |
Khoom Loj:
Product Application Diagra:
Yuav ua li cas xaiv lub fiber optic transceiver?
Optical fiber transceivers rhuav tshem 100-meter txwv ntawm Ethernet cables hauv cov ntaub ntawv xa mus.Kev cia siab rau kev ua haujlwm siab hloov cov chips thiab lub peev xwm loj, thaum ua tiav qhov tsis thaiv kev sib kis thiab kev hloov pauv kev ua tau zoo, lawv kuj muab cov tsheb sib npaug, kev sib cais thiab kev tsis sib haum xeeb.Kev tshawb nrhiav yuam kev thiab lwm yam haujlwm ua kom muaj kev ruaj ntseg thiab ruaj khov thaum lub sijhawm xa cov ntaub ntawv.Yog li ntawd, cov khoom siv fiber ntau optic transceiver tseem yuav yog ib feem tseem ceeb ntawm kev tsim network tiag tiag rau lub sijhawm ntev.Yog li, peb yuav tsum xaiv fiber ntau optic transceivers li cas?
1. Chaw nres nkoj ua haujlwm kuaj
Feem ntau sim seb txhua qhov chaw nres nkoj tuaj yeem ua haujlwm li cas hauv lub xeev duplex ntawm 10Mbps, 100Mbps thiab ib nrab-duplex xeev.Nyob rau tib lub sijhawm, nws yuav tsum tau sim seb txhua qhov chaw nres nkoj tuaj yeem xaiv qhov kev sib kis ceev tshaj plaws thiab txiav txim siab qhov sib kis ntawm lwm cov khoom siv.Qhov kev xeem no tuaj yeem suav nrog hauv lwm qhov kev xeem.
2. Kev ntsuas kev sib haum xeeb
Nws tsuas yog ntsuas qhov kev sib txuas muaj peev xwm ntawm optical fiber transceiver thiab lwm yam khoom siv sib xws nrog Ethernet thiab Fast Ethernet (xws li daim npav network, HUB, Hloov, daim npav kho qhov muag, thiab hloov kho qhov muag).Qhov yuav tsum tau muaj peev xwm txhawb nqa kev sib txuas ntawm cov khoom sib xws.
3. Cable kev twb kev txuas yam ntxwv
Kuaj cov fiber ntau optic transceiver lub peev xwm los pab txhawb cov cables.Ua ntej, sim qhov kev sib txuas muaj peev xwm ntawm Qeb 5 network cables nrog qhov ntev ntawm 100m thiab 10m, thiab kuaj qhov muaj peev xwm sib txuas ntawm Qeb 5 network cables ntev (120m) ntawm ntau hom.Thaum lub sij hawm xeem, qhov chaw nres nkoj kho qhov muag ntawm lub transceiver yuav tsum muaj kev sib txuas muaj peev xwm ntawm 10Mbps thiab tus nqi ntawm 100Mbps, thiab qhov siab tshaj plaws yuav tsum muaj peev xwm txuas mus rau tag nrho-duplex 100Mbps yam tsis muaj qhov yuam kev.Qeb 3 twisted khub cables yuav tsis raug kuaj.Subtests tuaj yeem suav nrog hauv lwm qhov kev xeem.
4. Cov yam ntxwv kis tau tus mob (kev kis tus nqi poob ntawm cov ntaub ntawv pob ntawm qhov ntev sib txawv, kev sib kis ceev)
Nws tsuas yog kuaj cov pob ntawv poob tus nqi thaum lub optical fiber transceiver optical chaw nres nkoj xa cov ntaub ntawv sib txawv, thiab kev sib txuas ceev raws li qhov sib txawv ntawm kev sib txuas.Rau cov pob ntawv poob tus nqi, koj tuaj yeem siv cov ntawv xeem software muab los ntawm daim npav network los kuaj cov pob ntawv poob thaum lub pob ntawv loj yog 64, 512, 1518, 128 (yeem) thiab 1000 (yeem) bytes nyob rau hauv cov nqi sib txawv., tus naj npawb ntawm pob ntawv yuam kev, tus naj npawb ntawm cov pob ntawv xa thiab tau txais yuav tsum yog ntau tshaj 2,000,000.Kev ntsuas kev sib kis ceev tuaj yeem siv ua 3, ping thiab lwm yam software.
5. Lub compatibility ntawm tag nrho lub tshuab mus rau kis tau tus mob network raws tu qauv
Nws tsuas yog ntsuas qhov sib xws ntawm fiber ntau optic transceivers rau network raws tu qauv, uas tuaj yeem sim hauv Novell, Windows thiab lwm qhov chaw.Cov txheej txheem qis hauv qab no xws li TCP/IP, IPX, NETBIOS, DHCP, thiab lwm yam yuav tsum tau sim, thiab cov txheej txheem uas yuav tsum tau tshaj tawm yuav tsum tau sim.Optical transceivers yuav tsum tau los txhawb cov kev cai no (VLAN, QOS, COS, thiab lwm yam).
6. Qhov ntsuas qhov ntsuas qhov ntsuas
Kuaj seb qhov xwm txheej ntawm qhov taw qhia lub teeb puas zoo ib yam nrog cov lus piav qhia ntawm lub vaj huam sib luag thiab cov neeg siv phau ntawv, thiab seb nws puas zoo ib yam nrog cov xwm txheej tam sim no ntawm fiber ntau optic transceiver.