8FE + 2GE WDM Media Converter (Ib hom Ib leeg-fiber SC)
8FE + 2GE WDM Media Converter (Ib hom Ib leeg-fiber SC)
Khoom nta:
Txaus siab tso tawm 100M 8 kho qhov muag 2 hluav taws xob ib hom ib leeg-fiber 20km B-kawg cov fiber ntau converter!
Huizhou Changfei Photoelectric Technology Co., Ltd. yog cov chaw tsim khoom lag luam ntawm cov khoom lag luam kev sib txuas lus thiab huab tswj cov khoom lag luam hauv Suav teb.Kev cog lus rau kev tsim kho tshiab thiab kev ua tau zoo, peb siv zog los muab cov kev daws teeb meem thiab cov kev pabcuam holistic kom tau raws li cov kev xav tau ntawm peb cov neeg siv khoom muaj txiaj ntsig.Nws yog nrog lub zeem muag hauv siab tias peb tau tsim cov khoom tshiab: 100G 8 optical 2 hluav taws xob ib hom ib leeg-fiber 20km B-kawg cov fiber ntau converter.
Tsim los rau kev ua tau zoo tshaj plaws, qhov siab tshaj fiber ntau optic transceiver yog lub zog hauv kev lag luam kev sib txuas lus.Nws cov khoom siv fiber ntau optic transceiver ua kom ntseeg tau thiab ruaj ntseg cov ntaub ntawv xa mus ntev txog li 20 mais.Nrog nws ib hom fiber ntau compatibility, nws muab unmatched ceev thiab kev ntseeg siab, ua rau nws ib tug zoo tagnrho tov rau Industrial Ethernet, Industrial Wireless, thiab network kev koom ua ke.
Peb 100 Gigabit 8 optical 2 hluav taws xob ib hom ib leeg-fiber 20km B-chaw nres nkoj cov fiber ntau converter yog nruab nrog SC interface kom yooj yim installation thiab txuas.Nws cov dynamic LED qhov taw qhia muab cov lus pom zoo tam sim ntawm cov khoom siv rau kev saib xyuas yooj yim thiab daws teeb meem.Plug thiab ua si, siv tau yooj yim heev, tsis tas yuav tsum tau teeb tsa ntxiv.
Thaum nws los txog rau kev lag luam kev sib txuas lus, kev ntseeg siab thiab kev siv yooj yim yog qhov tseem ceeb.Rau peb cov khoom, peb ua tib zoo xav txog cov xwm txheej no.100 Gigabit 8 Optical 2 Hluav Taws Xob Ib Hom Ib Leeg Fiber 20km B-Terminal Digital Fiber Converter tsis tsuas yog ua tau raws li cov cai no, tab sis tshaj lawv.Nws txoj kev tsim kho muaj zog thiab kev siv thev naus laus zis tau lav ruaj khov thiab ruaj ntseg cov teeb liab kis tau tus mob, txawm tias nyob rau hauv kev sib tw kev lag luam ib puag ncig.
Nrog Huizhou Changfei Optoelectronics Technology Co., Ltd. qhov kev paub dhau los thiab kev txawj ntse hauv kev lag luam kev sib txuas lus, koj tuaj yeem ntseeg tau tias cov khoom no tau tsim thiab tsim los rau cov qauv siab tshaj plaws.Peb qhov kev cog lus rau tag nrho cov kev daws teeb meem txhais tau tias peb txhawb koj txhua kauj ruam ntawm txoj kev, los ntawm kev xaiv cov khoom mus rau kev teeb tsa.
Hauv kev xaus, 100G 8 Optical 2 Hluav Taws Xob Ib Hom Ib Leeg Fiber 20km B Chaw nres nkoj Digital Fiber Converter yog ib qho pov thawj rau peb txoj kev mob siab rau kev ua tau zoo.Nws cov yam ntxwv siab heev, suav nrog SC interface, dynamic LED ntsuas thiab yooj yim plug-and-play functionality, ua rau nws xaiv zoo meej rau koj cov kev xav tau kev sib txuas lus.Peb ntseeg hais tias Huizhou Changfei Photoelectric Technology Co., Ltd. tuaj yeem muab kev sib txuas lus thoob ntiaj teb rau koj.Koom nrog peb hauv kev puag yav tom ntej ntawm kev lag luam kev sib txuas lus thiab ua ib feem ntawm peb cov zej zog loj hlob ntawm cov neeg siv khoom txaus siab.
Technical Parameter:
Qauv | CF-8F12GSW-20B | |
Interface yam ntxwv | ||
Tsau Chaw nres nkoj | 2 * 10/100/1000Base-T RJ45 chaw nres nkoj8 * 155M uplink SC fiber chaw nres nkoj | |
Ethernet Chaw nres nkoj | 10/100/1000Base-T auto-sensing, puv / ib nrab duplex MDI / MDI-X tus kheej hloov | |
Twisted PairKev sib kis | 10BASE-T: Cat3,4,5 UTP(≤100 meter)100BASE-T: Cat5e lossis tom qab UTP (≤100 meter)1000BASE-T : Cat5e lossis tom qab UTP (≤100 meter) | |
Optical Chaw nres nkoj | Default optical module yog ib hom ib leeg-fiber 20km, SC chaw nres nkoj | |
Wavelength / nrug | A-kawg: RX1310nm / RX1550nm 0 ~ 40KMB-kawg: RX1550nm / RX1310nm 0 ~ 40KM | |
A-kawg: RX1490nm / RX1550nm 0 ~ 120KMB-kawg: RX1550nm / RX1490nm 0 ~ 120KM | ||
Chip Parameter | ||
Network raws tu qauv | IEEE 802.3 10BASE-T, IEEE 802.3i 10Base-T,IEEE 802.3u 100Base-TX, IEEE 802.3u 100Base-FX, IEEE 802.3xIEEE 802.3ab 1000Base-T; IEEE 802.3z 1000Base-X; | |
Kev xa tawm hom | Khw muag khoom thiab xa mus (Tag Nrho Hlau Ceev) | |
Hloov Peev Xwm | 5.6gbps ua | |
Buffer Nco | 4.16Mp ib | |
MAC | 2 K | |
Qhov taw qhia LED | Fiber ntau | FX1 (ntsuab)-FX8 (ntsuab) |
Ntawm lub rooj zaum RJ45 | 1X-2X Yellow: Qhia PoE | |
1X-2X Ntsuab: Qhia txog kev ua haujlwm hauv network | ||
Hwj chim | PWR (ntsuab) | |
Hwj chim | ||
Ua haujlwm Voltage | AC: 100-240V | |
Kev siv fais fab | Standby <3W, Full load <10W | |
Fais fab mov | DC: 5V / 2A industrial fais fab mov | |
Kev tiv thaiv xob laim & Daim ntawv pov thawj | ||
xob tiv thaiv | Kev tiv thaiv xob laim: 4KV 8/20us, Kev tiv thaiv qib: IP30 | |
Daim ntawv pov thawj | CCC; CE cim, lag luam;CE/LVD EN60950; FCC Tshooj 15 Chav B;RoHS | |
Lub cev Parameter | ||
Kev ua haujlwm TEMP | -20 ~ + 55 ° C; 5% ~ 90% RH Tsis condensing | |
Cia TEMP | -40 ~ + 85 ° C; 5% ~ 95% RH Tsis condensing | |
Qhov Loj (L * W * H) | 220mm * 101mm * 28mm | |
Kev teeb tsa | Desktop |
Khoom Loj:
Product Application Diagra:
Yuav ua li cas xaiv lub fiber optic transceiver?
Optical fiber transceivers rhuav tshem 100-meter txwv ntawm Ethernet cables hauv cov ntaub ntawv xa mus.Kev cia siab rau kev ua haujlwm siab hloov cov chips thiab lub peev xwm loj, thaum ua tiav qhov tsis thaiv kev sib kis thiab kev hloov pauv kev ua tau zoo, lawv kuj muab cov tsheb sib npaug, kev sib cais thiab kev tsis sib haum xeeb.Kev tshawb nrhiav yuam kev thiab lwm yam haujlwm ua kom muaj kev ruaj ntseg thiab ruaj khov thaum lub sijhawm xa cov ntaub ntawv.Yog li ntawd, cov khoom siv fiber ntau optic transceiver tseem yuav yog ib feem tseem ceeb ntawm kev tsim network tiag tiag rau lub sijhawm ntev.Yog li, peb yuav tsum xaiv fiber ntau optic transceivers li cas?
1. Chaw nres nkoj ua haujlwm kuaj
Feem ntau sim seb txhua qhov chaw nres nkoj tuaj yeem ua haujlwm li cas hauv lub xeev duplex ntawm 10Mbps, 100Mbps thiab ib nrab-duplex xeev.Nyob rau tib lub sijhawm, nws yuav tsum tau sim seb txhua qhov chaw nres nkoj tuaj yeem xaiv qhov kev sib kis ceev tshaj plaws thiab txiav txim siab qhov sib kis ntawm lwm cov khoom siv.Qhov kev xeem no tuaj yeem suav nrog hauv lwm qhov kev xeem.
2. Kev ntsuas kev sib haum xeeb
Nws tsuas yog ntsuas qhov kev sib txuas muaj peev xwm ntawm optical fiber transceiver thiab lwm yam khoom siv sib xws nrog Ethernet thiab Fast Ethernet (xws li daim npav network, HUB, Hloov, daim npav kho qhov muag, thiab hloov kho qhov muag).Qhov yuav tsum tau muaj peev xwm txhawb nqa kev sib txuas ntawm cov khoom sib xws.
3. Cable kev twb kev txuas yam ntxwv
Kuaj cov fiber ntau optic transceiver lub peev xwm los pab txhawb cov cables.Ua ntej, sim qhov kev sib txuas muaj peev xwm ntawm Qeb 5 network cables nrog qhov ntev ntawm 100m thiab 10m, thiab kuaj qhov muaj peev xwm sib txuas ntawm Qeb 5 network cables ntev (120m) ntawm ntau hom.Thaum lub sij hawm xeem, qhov chaw nres nkoj kho qhov muag ntawm lub transceiver yuav tsum muaj kev sib txuas muaj peev xwm ntawm 10Mbps thiab tus nqi ntawm 100Mbps, thiab qhov siab tshaj plaws yuav tsum muaj peev xwm txuas mus rau tag nrho-duplex 100Mbps yam tsis muaj qhov yuam kev.Qeb 3 twisted khub cables yuav tsis raug kuaj.Subtests tuaj yeem suav nrog hauv lwm qhov kev xeem.
4. Cov yam ntxwv kis tau tus mob (kev kis tus nqi poob ntawm cov ntaub ntawv pob ntawm qhov ntev sib txawv, kev sib kis ceev)
Nws tsuas yog kuaj cov pob ntawv poob tus nqi thaum lub optical fiber transceiver optical chaw nres nkoj xa cov ntaub ntawv sib txawv, thiab kev sib txuas ceev raws li qhov sib txawv ntawm kev sib txuas.Rau cov pob ntawv poob tus nqi, koj tuaj yeem siv cov ntawv xeem software muab los ntawm daim npav network los kuaj cov pob ntawv poob thaum lub pob ntawv loj yog 64, 512, 1518, 128 (yeem) thiab 1000 (yeem) bytes nyob rau hauv cov nqi sib txawv., tus naj npawb ntawm pob ntawv yuam kev, tus naj npawb ntawm cov pob ntawv xa thiab tau txais yuav tsum yog ntau tshaj 2,000,000.Kev ntsuas kev sib kis ceev tuaj yeem siv ua 3, ping thiab lwm yam software.
5. Lub compatibility ntawm tag nrho lub tshuab mus rau kis tau tus mob network raws tu qauv
Nws tsuas yog ntsuas qhov sib xws ntawm fiber ntau optic transceivers rau network raws tu qauv, uas tuaj yeem sim hauv Novell, Windows thiab lwm qhov chaw.Cov txheej txheem qis hauv qab no xws li TCP/IP, IPX, NETBIOS, DHCP, thiab lwm yam yuav tsum tau sim, thiab cov txheej txheem uas yuav tsum tau tshaj tawm yuav tsum tau sim.Optical transceivers yuav tsum tau los txhawb cov kev cai no (VLAN, QOS, COS, thiab lwm yam).
6. Qhov ntsuas qhov ntsuas qhov ntsuas
Kuaj seb qhov xwm txheej ntawm qhov taw qhia lub teeb puas zoo ib yam nrog cov lus piav qhia ntawm lub vaj huam sib luag thiab cov neeg siv phau ntawv, thiab seb nws puas zoo ib yam nrog cov xwm txheej tam sim no ntawm fiber ntau optic transceiver.