9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj Ethernet Hloov (Sib-hom Ib-fiber SC)

Lus piav qhia luv luv:

CF-WS210S1A-1F8T-20 yog tag nrho Gigabit L2 WEB tswj Ethernet fiber ntau hloov nws tus kheej tsim los ntawm CF FIBERLINK.Nws muaj 8 * 10/100/1000Base-T RJ45 chaw nres nkoj thiab 1 * 100/1000Base-X SC chaw nres nkoj.Txhua qhov chaw nres nkoj tuaj yeem txhawb nqa xaim xaim nrawm.Qhov kev hloov ua ke nrog lub bypass optical switching module.Thaum lub hwj huam mov ntawm qhov hloov pauv tau cuam tshuam, cov khoom siv kho qhov muag tau hloov mus rau hauv lub xeev bypass-los ntawm lub xeev kom tsis txhob muaj kev cuam tshuam kev sib txuas lus vim hloov tsis ua haujlwm thiab xyuas kom muaj kev ntseeg siab ntawm kev sib txuas lus network.

CF-WS210S1A-1F8T-20 muaj L2 WEB network tswj kev ua haujlwm, ua tiav kev tiv thaiv kev ruaj ntseg, ACL / QoS txoj cai thiab nplua nuj VLAN ua haujlwm, yooj yim los tswj thiab tswj.Txhawb ntau lub network redundancy raws tu qauv STP / RSTP (<50ms), los txhim kho qhov txuas thaub qab thiab kev ntseeg siab ntawm lub network kom ntseeg tau tias tsis muaj kev cuam tshuam kev sib txuas lus ntawm cov ntawv thov tseem ceeb.Raws li cov kev xav tau tiag tiag, kev tswj chaw nres nkoj, tswj chaw nres nkoj, kev faib VLAN, IGMP, txoj cai tswjfwm kev nyab xeeb thiab lwm yam kev pabcuam kev pabcuam raug ua los ntawm Web thiab lwm txoj hauv kev tswj xyuas network.Lub plhaub yog ua los ntawm cov hlau alloy, uas muaj kev lag luam zoo ib puag ncig kev hloov pauv (xws li kev ruaj ntseg txhua yam, kev nyab xeeb ib puag ncig adaptability, electromagnetic ib puag ncig adaptability, thiab lwm yam), kev tiv thaiv qib yog IP40, qis zog noj thiab tsis muaj kiv cua, 5 xyoo warranty.Nws yog tsim rau tsev kawm ntawv, tsev so thiab enterprise Campus network network nkag, convergence thiab core application scenarios.


Product Detail

Khoom cim npe

9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj Ethernet Hloov (Sib-hom Ib-fiber SC)

Khoom nta:

 Gigabit nkag, SFP fiber ntau chaw nres nkoj uplink, Integrated Bypass muaj nuj nqi

◇ Txhawb nqa tsis thaiv cov xaim xaim nrawm.

◇ Txhawb nqa puv-duplex raws li IEEE802.3x thiab ib nrab-duplex raws li Backpressure.

◇ Txhawb Gigabit Ethernet chaw nres nkoj thiab Gigabit SFP chaw nres nkoj ua ke, uas ua rau cov neeg siv yooj yim tsim kev sib tham kom tau raws li qhov xav tau ntawm ntau yam xwm txheej.

◇ Txhawb nqa lub cev ib hom ib leeg fiber ntau optical txoj kev (Bypass) muaj nuj nqi, kev hloov kho khoom siv dawb huv, lub sijhawm hloov luv luv, tsis cuam tshuam rau cov ntaub ntawv xa mus thiab txhim kho kev ruaj ntseg ntawm lub network.

 Network tswj thiab ceev lub nplhaib muaj nuj nqi

◇ STP/RSTP/MSTP.

◇ Static thiab dynamic aggregation.

◇ IEEE 802.1Q VLAN, hloov pauv VLAN faib, Nkag mus, Lub cev thiab Hybrid.

◇ QoS, Qhov tseem ceeb hom raws li 802. 1P, Chaw nres nkoj & DSCP, kev teem caij teem caij algorithm suav nrog EQU, SP, WRR & SP + WRR.

◇ IGMP Snooping V1/V2/V3 ua tau raws li ntau lub davhlau ya nyob twg siab-txhais yees duab soj ntsuam thiab kev sib tham hauv video.

◇ ALC, lim cov ntaub ntawv pob ntawv los ntawm kev teeb tsa cov kev cai sib txuam, kev ua haujlwm & sijhawm tso cai, thiab muab kev tswj tau yooj yim thiab nyab xeeb.

 Kev ruaj ntseg

◇ 802. 1X authentication.

◇ Chaw nres nkoj cais, tswj cua daj cua dub.

◇ IP-MAC-VLAN-Port khi.

 ruaj khov thiab txhim khu kev qha

◇ CCC, CE, FCC, RoHS.

◇ Tsawg zog noj, Tsis muaj kiv cua, Hlau alloy plhaub.

◇ Lub vaj huam sib luag tus neeg siv tuaj yeem pom cov cuab yeej xwm txheej dhau los ntawm LED qhov taw qhia ntawm PWR, SYS, Txuas, L / A.

 One-stop chaw taws teeb tswj thiab tswj

◇ HTTPS, SSLV3, thiab SSHV1/V2.

◇ RMON, lub kaw lus kaw lus, LLDP, thiab chaw nres nkoj kev txheeb cais.

◇ CPU saib xyuas, kev soj ntsuam nco, Ping kuaj, thiab kuaj kab mob.

◇ Web tswj, SNMP (V1/V2/V3).

Technical Parameter:

 

Qauv

 

CF-WS210S1A-1F8T-20

 

Interface yam ntxwv

 

 

Tsau Chaw nres nkoj

 

8 * 10/100/1000Base-T RJ45 chaw nres nkoj

1 * 100/1000Base-X uplink SC chaw nres nkoj

 

Ethernet Chaw nres nkoj

 

Chaw nres nkoj 1-8 txhawb 10/100/1000Base-T pib-sensing, puv / ib nrab duplex

MDI/MDI-X tus kheej hloov

 

 

Twisted Pair

Kev sib kis

 

10BASE-T: Cat3,4,5 UTP(≤100 meters)

100BASE-TX: Cat5 lossis tom qab UTP(≤100 meters)

1000BASE-T: Cat5e lossis tom qab UTP (≤100 meters)

 

SFP qhov chaw nres nkoj

Default optical module yog ib hom ib leeg-fiber 20km, SC chaw nres nkoj
Wavelength / nrug A-kawg: RX1310nm / RX1550nm 0 ~ 40KM

B-kawg: RX1550nm / RX1310nm 0 ~ 40KM

A-kawg: RX1490nm / RX1550nm 0 ~ 120KM

B-kawg: RX1550nm / RX1490nm 0 ~ 120KM

 

Chip Parameter

 

Network

Hom kev tswj hwm

 

 

L2 (WEB kev tswj hwm)

Ob hom kev ua haujlwm Toggle hloov: WEB network tswj hom / VLAN cais hom
 

Network raws tu qauv

 

IEEE 802.3 10BASE-T, IEEE 802.3i 10Base-T, IEEE 802.3u 100Base-TX

IEEE 802.3ab 1000Base-X, IEEE 802.3z 1000Base-X, IEEE 802.3x

 

Kev xa tawm hom

 

Khw muag khoom thiab xa mus (Tag Nrho Hlau Ceev)

 

Hloov Peev Xwm

 

18 Gbps

 

Buffer Nco

 

13.4Mp ib

 

MAC

 

8K

Qhov taw qhia LED

 

PowerIndicatorLight  

P1: 1 Green

Fiber Indicator Lub teeb 9: 1 Ntsuab (Txuas, SDFED)
Ntawm lub rooj zaum RJ45

 

1-8 Yellow: Qhia PoE
1-8 Ntsuab: Qhia txog kev ua haujlwm hauv network
Rov pib dua Nias thiab tuav lub khawm pib dua rau 10s thiab tso nws kom rov qab tau cov

Hoobkas nqis

 

 

Hwj chim
Ua haujlwm Voltage  

DC12-57V, 4 Pin muaj phoenix davhlau ya nyob twg, txhawb kev tiv thaiv rov qab

 

Kev siv fais fab

 

Standby <6W, Full load <8W

Fais fab mov  

12V / 2A industrial fais fab mov

Ntawv pov thawj & Warranty
Kev tiv thaiv hluav taws xob Kev tiv thaiv xob laim: 6KV 8/20us, Kev tiv thaiv qib: IP40
Network interface

surge tiv thaiv

IEC 61000-4-5 Qib 4 (4KV) (10/700us)
Neeg kho tshuab

Cov khoom

IEC 60068-2-6 (kev tiv thaiv kev vibration), IEC60068-2-27 (tiv thaiv kev poob siab)

IEC 60068-2-32 (Lub caij nplooj zeeg dawb)

 

Daim ntawv pov thawj

 

CCC, CE mark, coj mus muag, CE/LVD EN62368-1, FCC Part 15 Class B,

RoHS

Lub cev Parameter
 

Ua haujlwm TEMP / Humidity

-40 ~ + 75 ° C; 5% ~ 90% RH Tsis condensing
 

Cia TEMP / Humidity

 

-40 ~ + 85 ° C; 5% ~ 95% RH Tsis condensing

 

Qhov Loj (L * W * H)

 

330mm * 172mm * 44mm

 

 

Kev teeb tsa

 

Desktop

Khoom Loj:

Product Application Diagra:

c65a66e0d1ea6cfb1a482e6aab1c18c

 

Q&A:

Koj tus nqi yog dab tsi?

Peb cov nqi yuav raug hloov raws li cov khoom siv thiab lwm yam kev lag luam.Peb yuav xa koj daim ntawv teev nqi tshiab tom qab koj lub tuam txhab tiv tauj peb kom paub ntxiv.

  Koj puas muaj qhov kev txiav txim yam tsawg kawg nkaus?

Yog lawm, peb xav kom txhua qhov kev txiav txim thoob ntiaj teb kom muaj qhov kev txiav txim yam tsawg kawg nkaus.Yog tias koj tab tom nrhiav rov muag tab sis hauv ntau qhov me me, peb xav kom koj mus saib peb lub vev xaib.

Koj puas tuaj yeem muab cov ntaub ntawv cuam tshuam?

Yog lawm, peb tuaj yeem muab cov ntaub ntawv feem ntau suav nrog Daim Ntawv Pov Thawj Kev Ntsuam Xyuas / Kev Ua Raws Cai;Kev pov hwm;Keeb kwm, thiab lwm yam ntaub ntawv export thaum xav tau.

Lub sij hawm ua khoom nruab nrab yog dab tsi?

Rau cov qauv, lub sijhawm ua haujlwm yog li 7 hnub.Rau kev tsim khoom loj, lub sijhawm ua haujlwm yog 20-30 hnub tom qab tau txais cov nyiaj them poob haujlwm.Lub sij hawm ua cov hmoov lead ua tau zoo thaum (1) peb tau txais koj qhov tso nyiaj, thiab (2) peb tau txais koj qhov kev pom zoo zaum kawg rau koj cov khoom.Yog tias peb lub sijhawm ua haujlwm tsis ua haujlwm nrog koj lub sijhawm kawg, thov mus hla koj qhov kev xav tau nrog koj qhov muag.Nyob rau hauv txhua rooj plaub peb yuav sim ua kom haum raws li koj xav tau.Feem ntau peb muaj peev xwm ua tau li ntawd.

Hom kev them nyiaj twg koj txais?

Koj tuaj yeem them nyiaj rau peb tus account hauv txhab nyiaj, Western Union lossis PayPal:
30% tso nyiaj ua ntej, 70% tshuav nyiaj li cas tiv thaiv daim B / L.

Qhov khoom warranty yog dab tsi?

Peb lav peb cov ntaub ntawv thiab kev ua haujlwm.Peb qhov kev cog lus yog kom koj txaus siab rau peb cov khoom.Hauv kev lees paub lossis tsis yog, nws yog kab lis kev cai ntawm peb lub tuam txhab los daws thiab daws txhua yam teeb meem ntawm cov neeg siv khoom kom txhua tus neeg txaus siab

Koj puas tau lees tias muaj kev nyab xeeb thiab nyab xeeb ntawm kev xa khoom?

Yog lawm, peb ib txwm siv cov khoom ntim zoo export.Peb kuj tseem siv cov ntim khoom tshwj xeeb rau cov khoom txaus ntshai thiab siv tau cov neeg xa khoom txias cia rau cov khoom kub.Cov khoom ntim tshwj xeeb thiab cov khoom ntim tsis yog tus qauv yuav raug them nqi ntxiv.

Yuav ua li cas txog tus nqi shipping?

Tus nqi shipping nyob ntawm txoj kev koj xaiv kom tau cov khoom.Kev nthuav qhia feem ntau yog qhov nrawm tshaj plaws tab sis kuj tseem kim tshaj.Los ntawm seafreight yog qhov kev daws teeb meem zoo tshaj plaws rau cov nyiaj loj.Raws nraim cov nqi thauj khoom peb tuaj yeem muab rau koj yog tias peb paub cov ntsiab lus ntawm tus nqi, qhov hnyav thiab txoj kev.Thov hu rau peb kom paub ntxiv.

 


  • Yav dhau los:
  • Tom ntej:

  • Sau koj cov lus ntawm no thiab xa tuaj rau peb

    Cov khoom muaj feem xyuam

    • 9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethernet Hloov (Ib hom Dual-fiber SC)

      9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Etherne ...

      9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethernet Hloov (Single-mode Dual-fiber SC) Khoom Nta:  Gigabit nkag, SC fiber chaw nres nkoj uplink, Integrated Bypass muaj nuj nqi ◇ Txhawb tsis-blocking hlau-ceev xa mus.◇ Txhawb nqa puv-duplex raws li IEEE802.3x thiab ib nrab-duplex raws li Backpressure.◇ Txhawb Gigabit Ethernet chaw nres nkoj thiab Gigabit SC chaw nres nkoj ua ke, uas ua rau cov neeg siv yooj yim tsim kev sib tham kom tau raws li qhov xav tau ntawm ntau yam xwm txheej.Intelligent PoE power sup ◇ ntsib lub ...

    • 9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethernet Hloov

      9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Etherne ...

      9-chaw nres nkoj 10/100M/1000M L2 WEB Tswj PoE Ethernet Hloov Cov Khoom Muag:  Gigabit nkag, gigabit SFP chaw nres nkoj uplink ◇ Txhawb tsis thaiv cov xaim xaim ceev.◇ Txhawb nqa puv-duplex raws li IEEE802.3x thiab ib nrab-duplex raws li Backpressure.◇ Txhawb Gigabit Ethernet chaw nres nkoj thiab Gigabit SFP chaw nres nkoj ua ke, uas ua rau cov neeg siv yooj yim tsim kev sib tham kom tau raws li qhov xav tau ntawm ntau yam xwm txheej. Intelligent PoE fais fab sup ◇ ntsib cov kev xav tau ntawm kev saib xyuas kev ruaj ntseg, kev sib tham hauv xov tooj ◇ s ...

    • 10-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj Ethernet Hloov (Ib hom Dual-fiber SC)

      10-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj Ethernet ...

      10-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj Ethernet Hloov (Single-mode Dual-fiber SC) Khoom Nta:  Gigabit nkag, SFP fiber ntau chaw nres nkoj uplink, Integrated Bypass muaj nuj nqi ◇ Txhawb tsis-blocking hlau-ceev xa mus.◇ Txhawb nqa puv-duplex raws li IEEE802.3x thiab ib nrab-duplex raws li Backpressure.◇ Txhawb Gigabit Ethernet chaw nres nkoj thiab Gigabit SFP chaw nres nkoj ua ke, uas ua rau cov neeg siv yooj yim tsim kev sib tham kom tau raws li qhov xav tau ntawm ntau yam xwm txheej.◇ Txhawb lub cev ib hom ib leeg fib...

    • 9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethernet Hloov (multi-mode Dual-fiber SC)

      9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Etherne ...

      9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethernet Hloov (multi-mode Dual-fiber SC) Khoom Nta:  Gigabit nkag, SC fiber chaw nres nkoj uplink, Integrated Bypass muaj nuj nqi ◇ Txhawb tsis-blocking hlau-ceev xa mus.◇ Txhawb nqa puv-duplex raws li IEEE802.3x thiab ib nrab-duplex raws li Backpressure.◇ Txhawb Gigabit Ethernet chaw nres nkoj thiab Gigabit SC chaw nres nkoj ua ke, uas ua rau cov neeg siv yooj yim tsim kev sib tham kom tau raws li qhov xav tau ntawm ntau yam xwm txheej.Intelligent PoE power sup ◇ ntsib lub n...

    • 9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj Ethernet Hloov (Ib hom Dual-fiber SC)

      9-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj Ethernet S...

      9-chaw nres nkoj 10/100M/1000M L2 WEB Tswj Ethernet Hloov (Single-mode Dual-fiber SC) Khoom Nta:  Gigabit nkag, SFP fiber ntau chaw nres nkoj uplink, Integrated Bypass muaj nuj nqi ◇ Txhawb tsis-blocking hlau-ceev xa mus.◇ Txhawb nqa puv-duplex raws li IEEE802.3x thiab ib nrab-duplex raws li Backpressure.◇ Txhawb Gigabit Ethernet chaw nres nkoj thiab Gigabit SFP chaw nres nkoj ua ke, uas ua rau cov neeg siv yooj yim tsim kev sib tham kom tau raws li qhov xav tau ntawm ntau yam xwm txheej.◇ Txhawb lub cev ib hom ib leeg fiber ntau ...

    • 10-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethernet Hloov (multi-mode Dual-fiber SC)

      10-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethern ...

      10-chaw nres nkoj 10/100M / 1000M L2 WEB Tswj PoE Ethernet Hloov (multi-mode Dual-fiber SC) Khoom Nta:  Gigabit nkag, SC fiber chaw nres nkoj uplink, Integrated Bypass muaj nuj nqi ◇ Txhawb tsis-blocking hlau-ceev forwarding.◇ Txhawb nqa puv-duplex raws li IEEE802.3x thiab ib nrab-duplex raws li Backpressure.◇ Txhawb Gigabit Ethernet chaw nres nkoj thiab Gigabit SC chaw nres nkoj ua ke, uas ua rau cov neeg siv yooj yim tsim kev sib tham kom tau raws li qhov xav tau ntawm ntau yam xwm txheej.Intelligent PoE power sup ◇ ntsib lub ...